Toyota 4 Runner/Hilux/Surf

1987-1998 of release

Repair and operation of the car



Toyota 4ranner
+ 1. Maintenance instruction
+ 2. Maintenance
+ 3. Engines
- 4. Systems of heating, ventilation
   4.1. Specifications
   4.2. Antifreeze
   4.3. Thermostat
   4.4. Krylchatka of the fan and hydraulic clutch
   4.5. Radiator and tank
   4.6. Oil cooler
   + 4.7. Pump
   4.8. Liquid temperature sensor
   4.9. Electric motor and chain of the fan of a heater
   4.10. Heater radiator
   4.11. Control panel of the conditioning block
   - 4.12. Air conditioning system
      4.12.1. Check of gas station of coolant
      4.12.2. Heater
   4.13. Compressor
+ 5. Fuel and exhaust systems
+ 6. Transmissions
+ 7. Transmission elements
+ 8. Brake system
+ 9. Suspension bracket and steering
+ 10. Body
+ 11. Electric equipment
+ 12. Electrical circuitries


2403db43

4.12. Air conditioning system

GENERAL INFORMATION

Air conditioning system of the Toyota 4 Runner/Hilux/Surt car of 1996

1. Main relay
2. Heater radiator
3. Main relay of a forward heater
4. Conditioner
5. Evaporator
6. Broad valve
7. Fan resistor
8. Thermoresistor
9. Amplifier
10. Back heater
11. Radiator
12. Electric motor
13. Main relay
14. Resistor
15. Control panel of a back heater
16. Switch
17. Condenser
18. Moisture separator
19. Compressor
20. Pressure relay
21. Heater gate
22. Control panel of the conditioner (switch, mode regulator, defrosting mode switch)

Prevention

The highway of air conditioning system is under high pressure. Before full removal of coolant it is forbidden to disconnect any hoses and to remove air conditioning system units.

Removal of coolant has to be carried out in car service.


Care of air conditioning system:

 – check of a state and tension of a compressor belt;
 – check of a condition of hoses and tubes (on to disunite the highway!);
 – cleaning of intercostal spaces of the condenser;
 – check of filling of system with coolant.

The conditioner should be turned on monthly approximately for 10 min.

Insufficient gas station of coolant is the most common cause of unsatisfactory operation of the conditioner. If noticeable temperature increase of air from the conditioner is observed, then check completeness of gas station of coolant.